Clean bench is what?

Release date:2017-05-15


Clean (Bench) is designed to meet the needs of the cleanliness of the local work areas in order to meet the needs of modern industry, optoelectronics industry, biological pharmacy and scientific research and experiment. Its working principle is: through the air blower the air inhaled through the static pressure box into the pre filter, HEPA filter, the filtered air to send a vertical or horizontal airflow, the operating area reached 100 clean, ensure the production of environmental cleanliness requirements.
Clean bench is divided into vertical flow clean bench according to the airflow direction (Vertical Flow Clean Bench) and the horizontal flow clean bench (Horizontal Flow Clean Bench), according to the operation structure is divided into unilateral and bilateral operation in two forms.
First, the working principle
The cleaning bench (hereinafter referred to as equipment) is a vertical laminar flow type local air purification equipment. Indoor air pre filter filtration, pressure in the static pressure box by small centrifugal fan, the air filter two filters, HEPA filter from the air outlet side blowing gas flow has a clean and uniform velocity, can eliminate the air the original work area, the dust particles and biological particles away. To form a sterile high clean working environment.
Two, structural features
The equipment is made of high quality steel plate bending, assembled and welded. The air supply body is provided with a novel non-woven fabric pre filter, an air efficient filter made of superfine glass fiber filter material, a small low-noise low speed centrifugal fan, etc., and is provided with a moving universal castor. The utility model has the advantages of simple structure, beautiful appearance and the like.
The equipment adopts VAV fan system, the input voltage regulator of the centrifugal fan, so as to change the condition, use the wind average wind speed remains in the ideal range, the main component of the equipment can effectively prolong the service life of the filter efficiency, reduce the running cost of the equipment, the equipment is also provided with an ultraviolet sterilizing device.
Five, installation:
1., the equipment should be installed in all levels of purification plant or sealed air-conditioning plant.
2. the equipment shall be installed away from the dust and source of high speed.
3. after installation, you must clean the equipment inside and its surroundings with super clean vacuum cleaner or no fiber producing tool.
4. after installation and cleaning, the QDF-2 type hot bulb anemometer can be used to measure the average wind speed in the cleaning area. When the average wind speed is less than 0.32m/s, high adjusting transformer voltage, increase the fan input voltage; on the contrary, when the average wind speed over 0.48m/s, lower voltage regulator, reduce fan input voltage until the average wind speed at 0.4m/s + 20% in the ideal range, can be used.
Six, use
1.. Before use, you should open the ultraviolet germicidal lamp 30 minutes ahead of time, deal with the microorganism in the working surface of the working table in the cleaning work area, turn off the germicidal lamp in 20 minutes, and start the blower.
2.. Do not store unnecessary items on the table so as to keep the clean air flow in the work area undisturbed.
3., regular (usually in February), using the QDF-2 heat bulb type anemometer to measure the average wind speed in the work area. If it is found that it does not meet the requirements, the fan power supply voltage can be adjusted, so that the work station is in the best working condition.
4.. This equipment can be operated by one person (single side table), and can also be operated by two persons (single sided double table).
Seven, maintenance
1.. According to the cleanliness of the environment, the filter material in the coarse filter will be removed and cleaned regularly. The interval is usually 3~6 months.
2. when the voltage of the air blower is raised to the maximum, the average wind speed in the work area can not reach the technical parameter index, and then the HEPA filter must be replaced.
3.. When changing the filter, first open the prefilter on the top of the air blower, then take the engine board. When changing, you should pay attention to the arrow mark of the filter, and the arrow point is the laminar flow direction.
4. after the filter is replaced, the dust detector is used to check whether the four surrounding seals are good, the fan unit voltage is adjusted, and the average wind speed in the work area is kept within the range of 0.4m/s + 20%. The cleaning efficiency is checked by a dust meter.
5., electrical components installed in the right side of the box, if there is electrical failure, you can refer to the electrical schematic diagram, electrical wiring diagram to be repaired.
L the 220V AC power must be cut off before installation and use, otherwise it will lead to danger!
L the installation and maintenance personnel must be strictly trained electrical technicians!
L the power line must be connected in series with the corresponding fuse. The housing is connected to the ground to ensure that the work is safe and reliable!
HT533A air flow controller instructions
L? Overview:
This product is one of the HT533 series air flow controllers. It is a special modulator for regulating the air quantity for the design and development of the cleaning table. There are eight lines of electrical appliances that regulate voltage memory. Touch keyboard operation and other functions.
L? Model classification?:
Type HT533A air volume controller for wind controller for vertical operation panel, type HT533B horizontal wind controller operation panel. The two types of controllers are only different in shape and have the same function.
L main technical parameters:
1? Working voltage: AC220V (10% - 15%, 50Hz +%1Hz)?;
2. output negative planting: MAX 220V/2A;
3. operating temperature: 0~50 DEG c;
4., work humidity: 40~90% (40 degrees Celsius) without condensation;
5. storage temperature: -20 DEG C ~ +70 DEG c;
6., opening size: 60mm * 110mm;
L? Working principle?:
1.. This product consists of two independent control components, that is, the main control panel HT533ACPU and the HT533OUT board which is composed of relay output. The operation key is attached to the controller's foil.
The 9V power supply of the 2. controller is provided by a primary winding of a single-phase self winding transformer for providing fan operation.
The 3. control panel is composed of indicating, touching keys and the running state surface of the fan.

The 4. panel uses a group of luminous tubes to indicate the size of the air flow, and controls the different air flow of the six files. The display is in order to increase, and each position of the air flow state is composed of a plurality of luminous units.
5., panels have "lighting" and "sterilization" two-way switch output instructions.
6. there are three keys:
L the "open / stop" key used to control the master fan switch. This key is a repeating key;
L "air volume adjustment" key used to control the decrease of air flow;
L the "lighting" key used to control the output of lighting;
L - a bactericidal key used to control the bactericidal output;
7. when the power on the first, in the absence of any touch key operation, the power supply instructions constantly flashing, status indicator light to two units as a unit of circular scanning. Other outputs without any instructions.
8. press the "open / stop" key, the power indicator lamp is constantly shining, and the control air quantity is output at the lowest speed.
9. only in the fan "open" case, you can operate the "air volume adjustment" button to adjust the output of the wind.
10. air flow control is realized by controlling the fan running voltage, and the air flow status display device represents the six speed of the air supply fan according to the increasing order, that is to say, the corresponding increase of the control air flow. In the first press "volume adjustment" button, KA1 for the relay pull in, a green light emitting device state indicator to display the corresponding instructions, the output voltage is "150V"; once again press "adjustment" button, relay KA1 relay KA2 is released, at the same time, a light emitting device and state according to a state of increasing forward. The third time presses the air volume adjustment key, the relay KA2 is released, the relay KA3 attracts, and the corresponding status light device is displayed to the third bit. And so on, in the sixth time, press the air volume adjustment key, the relay KA6 pull in, the relay KA5 release, and the light emitting device displays the "220V" state position, and the twenty light-emitting units emit green light.
11 in the KA6 relay output, "220V" state a total of twenty light emitting unit on the display, show that the maximum air flow control, then press "adjustment" button, the control output will once again return to the first step, this repeated cycle.
12. any unit of air volume (output voltage), when the output, press the "open / stop" key, control output, display bit will be closed.
13. relay KA1, KA2, KA3, KA4, KA5, KA6 output interlock, and when any of them has output, the other five are closed accordingly.
14 "lighting" and "sterilization" is the two independent control switch, in any case, it can press the "lighting" button, open or close the lighting output, and the "sterilization" button to open or close the sterilizing output, the two keys are repeated key function.
The 15. HT533BCPU board is connected with the HT533OUT through a long 800mm ten core cable, and the HT533 transformer of the HT533OUT board is fixed on the HT533 fixing rack. The connecting terminal is connected with the plug terminal.
16. when the controller is power-off, the time interval for power on should not be less than 5 seconds, otherwise it will cause fan malfunction.
17. controller panel length is 130mm, the width is 75mm.

The article keywords: