Daily maintenance and maintenance of paint room

Release date:2017-05-15


Maintenance of the filtration system
The filter system is an important part of spray booth, filtration system general spray paint room, by the following materials: primary filter sub high efficiency filter cotton, cotton, glass fiber filter felt, activated carbon.
At the beginning of 1, the filter cotton is mainly used for the first time the original air filter, the replacement cycle for 100 hours, also depending on the particular circumstances;
2, efficient filter cotton used for two times of air filtration, the replacement cycle for 400 hours;
3, glass fiber filter felt is mainly used for organic waste collection, usually have two paint room glass fiber filter, the replacement cycle is generally 80-120 hours;
4, activated carbon adsorption for paint paint mist exhaust, please check every 7 days if the activated carbon filters, activated carbon surface covered with paint effects of exhaust, the activated carbon should be replaced in a timely manner, to ensure smooth ventilation.

Maintenance seal
In order to ensure the sealing performance of the spray paint room, the seal in the spray paint room, the spray booth in operation, the internal gas is corrosive, and paint room seals are mostly rubber parts, its corrosion resistance is poor, therefore, in the process of using paint room must, depending on the actual situation of the seal replacement, at the same time, the connection parts of the barn sealant for long-term use will appear aging phenomenon, this time should be considered the actual situation of cleaning the old sealant, re sealed by a sealant treatment, to ensure that the air in the operation room clean.

Maintenance of electrical components
The control system is spray paint room "brain", it directs the spray booth to complete the operation, therefore, it is very important to ensure the control of components of the stable performance, in the process of using, the performance shall be tested for its components regularly, to ensure that it can accurately perform all the instructions and successfully complete the job.

Maintenance of transmission parts
The transmission barn is mainly between the drive motor and fan, due to the use of relatively frequent, paint room at work after a period of time, the motor and the fan drive belt will have a certain degree of loosening and wear, depending on the specific circumstances at the same time we must adjust the belt tensioning degree, make replacement when necessary, to ensure fan operation to achieve the best effect, in addition, has the oil hole in the bearing fan cover on both sides, should be regularly on bearing lubricating oil filling fan, to ensure its smooth operation.

Burner maintenance
The main burner provides a heat source for the paint room, by fuel, fuel oil and gas can be divided into two types, the fuel burner, maintenance are: regular inspection of tubing, ensure the tubing without leakage; regularly check the diesel filter, ensure no clogging; regular cleaning nozzle; air filter replacement burner regularly, to ensure clean air.

Other daily maintenance
In order to ensure the performance of spray paint room, should also do other necessary daily maintenance, mainly include: ensuring the room health check tightness of the bolt connections, check the real environment around the body, to ensure that the paint room without security risks in the process of using. Note: all repair and maintenance work must be carried out by qualified personnel, in the process of repair and maintenance must be guaranteed to do the following:
Do not put any workpiece a, paint room in;
B, turn off the paint room, the total power supply, and warning signs set in the general power supply;
C, all replaced cottonopolis to filter for special treatment, not like ordinary garbage treatment old cotton filter.